1 d
Code 14 bryant furnace?
Follow
11
Code 14 bryant furnace?
Hello, I have a 15 year old Bryant 90 Plus furnace and I keep getting error code 14, which says it is “ignition lockout”. 14—Single-Stage Furnace with 2-Speed Outdoor Unit Notes: 1. In this HVAC Training Video, I Show How to Troubleshoot Gas Furnace LED Error Code Problems. View and Download Bryant 395CAV specifications online. (If the thermostat is in the "cool" position, the furnace blower should be running. Bryant sells about 20 models of gas furnaces along with a few oil furnace models in the same three product lines, with the gas furnaces offered at 80% to 98. You need to check if the gas valve wiring is correct. /HVAC Repair | 24/7 Heating and Cooling Emergency Service – Get Expert Help Fast! / Furnace Repair Guide – Costs, Common Issues & Troubleshooting Tips Find product manuals and documements for your heating and cooling systems with the Bryant hvac document finder. AFUE rating: Bryant offers furnaces ranging from 80% AFUE to 98. Hello, I have a 15 year old Bryant 90 Plus furnace and I keep getting error code 14, which says it is “ignition lockout”. we check the voltage to igniter there is 120 volt p. You need to check if the gas valve wiring is correct. When it comes to replacing a furnace, homeowners often face several decisions that can impact the overall cost. I thought that might apply as well, but it specifically says the modulating furnace design avoids this. I did remove the wires connected to the gas valve to check voltage. Also for: 320aaz, 321aaz. Bryant gas furnaces. ISO Code -Shipping Point. But the work has to be done by a Bryant dealer to get that warranty, usually. Fix the problem by replacing the ignitor, resetting the circuit breaker, cleaning the burners, and cleaning or replacing the furnace filter. and had nearly 400,000 page views in 30 days. View online or download Bryant 395CAV Installation, Start-Up, Check Safety Controls Checklist Bryant 395CAV Information Manual (11 pages) Introduced-Combustion Gas Furnace Bryant Upflow Gas Furnace User's Information Manual Find many great new & used options and get the best deals for HK42FZ013 Carrier Bryant Cepl130438 Furnace Control Board at the best online prices at eBay! Free shipping for many products! This Bryant forced-air, natural gas furnace that's about 2 years old. So far the inducer motor, pressure switch, and the control board have been replaced. What is code 14 on a Bryant furnace? Published by Anaya Cole on 08/25/2022 What is code 14 on a Bryant furnace? How do you read Bryant codes? My furnace works for a few hours or less then the code 34, (ignition proving failure) then the code 14 (ignition lockout). This article from TEK Climate explains common furnace error messages. If you’ve noticed your Bryant furnace’s LED blinking three times, it’s an indication that there’s an issue with your furnace. LED CODE DESCRIPTION; RED LED1 ON: Furnace is operating in emergency heat. It started happening maybe once a month, then once a week and now it's starting to get really bad, I. Bryant Heating & Cooling offers heating and air conditioning systems to meet your needs. Based on factors such as the furnace’s age and condition, they will recommend either furnace repair or replacement. It got to the part where it supplies … View and Download Bryant 355MAV troubleshooting manual online. View online or download Bryant 310JAV User Manual. I've asked them to escalate to Bryant. However, like any other appliance, they can experience problems from time to time. We went to the job site found this carrier furnace showed error code # 14 and furnace blowing cold air. Ignitor does not glow or get hot. Gas and Oil Home Heating Furnaces - Bryant 90i furnace error code 24 - We have a Bryant 355mav050120. I then took my pvc pipe off from the inducer motor exhaust and it ran with no problem #14 · Nov 10, 2013. Hi everyone, I have a high efficiency Bryant furnace model# 355mav042080 that is experiencing occassional ignition lockouts (LED code 14) and most successful ignitions occur on the second attempt. Indices Commodities Currencies Stocks Heating systems are usually trouble-free and easy to maintain. Indices Commodities Currencies Stocks The Insider Trading Activity of Bryant Ellen H on Markets Insider. Join Date Dec 2020 Location Boston, MA Posts 5 Post Likes Likes (Given) 1 Likes (Received) 0 Dislikes (Given) 0 Dislikes (Received) 0 Bryant Gas Furnace Trade-In Allowance Brochure Published Date: 1/13/2023; Bryant Geothermal Comfort Systems Consumer Brochure Published Date: 1/14/2021; Bryant Heat Pump Comparison (with 38MURA) Brochure Published Date: 3/14/2023; Bryant HP Comparison Consumer Brochure Published Date: 6/14/2024; Bryant Humidifiers Consumer Brochure Published. 926TC furnace pdf manual download. I wiggled each and every wire, cleaned the filters, and said a small prayer; however, no go. Ultra Low NOx burner technology- meets 14 ng/J NOx emissions limit for California's South Coast Air Quality Management District and San Joaquin Air Pollution Control District. Traffic on JustAnswer rose 14 percent. 9) If you can clean the burners (I can't see them so if they are dirty you may have delayed ignition problems causing. As of 2014, Kobe Bryant had five basketball championship rings. This is really a joke an I cannot recommend a Bryant furnace at this point. In this HVAC Training Video, I Show How to Troubleshoot Gas Furnace LED Error Code Problems. RED LED2 ON: The microprocessor has malfunctioned. Most models are ENERGY STAR certified so you can be confident in an energy efficient unit that will save on your heating bills. AFUE rating: Bryant offers furnaces ranging from 80% AFUE to 98. Variable-Speed, Gas-Fired Condensing Furnaces. Shop by Popular Bryant Furnace Models. CONTROL WILL AUTO-RESET IN 3 HR. Two-Stage, Non-Communicating, Variable 25-Speed, ECM Multipoise, Condensing Gas Furnace with InteliSense. With so many options available in the market, finding a rel. If the calculated Customer: I have a Bryant Plus 80 furnace flashing a 14 code - Ignition lockout. Are you ready to become an expert troubleshooter of your Bryant furnace? Let’s dive in! The Bryant Plus 90 furnace is known for its efficiency and reliability. Is your old furnace giving you trouble? Are you tired of spending money on constant repairs? It may be time to consider cost-effective solutions for your old furnace repair When it comes to heating your home, gas furnaces are one of the most cost-effective options. He is person that will grow and thrive to learn more about the HVAC industry throughout his career. 4-way multipoise variable-capacity condensing gas furnace (40 pages). I cycled the breaker to the furnace, and the igniter switch on the furnace. I just had a new Bryant Evolution 986T 80K BTU dual zone furnace (2 stage heat with variable fan + AC condenser) installed. 5 days ago · Bryant’s lineup of gas furnaces has plenty to offer, with 15 furnace models delivering up to 98. After repairs are made, you can turn the furnace off for 60 seconds and back on again to reset the error code quickly. Bryant plus 90 - code 34 and after code 14. Are you ready to become an expert troubleshooter of your Bryant furnace? Let’s dive in! The Bryant Plus 90 furnace is known for its efficiency and reliability. Jan 4, 2024 · If you’ve tried all the steps in our Bryant furnace troubleshooting checklist with no luck, contact a professional HVAC contractor to inspect your furnace and make an accurate diagnosis. Join Date: Jan 2014 Posts: 4 Received 0 Upvotes on 0 Posts. Red LED2 Flashing: Reversed line voltage polarity. If you own a Bryant Plus 90 furnace, you know it’s a fantastic beast when running smoothly. Efficient operation is a function of good maintenance. 8) If you can take the vent off the top of the furnace and look down into the inducer and make sure it spins freely. Fix the problem by replacing the ignitor, resetting the circuit breaker, cleaning the burners, and cleaning or replacing the furnace filter. After resetting the code 14 lockout, it flashed a code 34- Ignition proving failure. Code 2-1: This is a sign of gas heating lockout. I would recommend this company to anyone who is looking for a professional job at a reasonable price For installation in SCAQMD only: This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit, and thus is subject to a mitigation fee of up to $450. How to Enter the Diagnostic Mode on a Carrier Infinity Thermostat?. fontaine real estate group 1 short and 4 long flashes. 9) If you can clean the burners (I can't see them so if they are dirty you may have delayed ignition problems causing. com, a non-DIY site and the ultimate Source for HVAC Information & Knowledge Sharing for the industry professional! Here you can join over 150,000 HVAC Professionals & enthusiasts from around the world discussing all things related to HVAC/R. 4-way multipoise variable-capacity condensing gas furnace (40 pages). Features To Consider for Bryant Furnaces. Bryant furnaces use gas or oil for fuel and have efficiency ratings of 803%, depending on the line and model you choose. CleanAirFurnaceRebate Hi. When it comes to purchasing a new furnace, finding a reliable and trustworthy dealer is crucial. How to Read a Bryant Serial Number. and had nearly 400,000 page views in 30 days. 33 code means it's overheating. In the manual after reading error code 14, it says to refer to code 34, which is “ignition proving failure”. View and Download Bryant 926TB installation, start-up, operating and service and maintenance instructions online In absence of local codes, the installation must comply with the national codes listed below and FURNACE RELIABILITY HAZARD all authorities having jurisdiction (MM) 14--- 3/16 14 x 25 x 3/4 Washable (360) (356 x 635 x 19. Tried cleaning the flame sensor- didn't help. 3% Annual Fuel Utilization Efficiency. I just had a new Bryant Evolution 986T 80K BTU dual zone furnace (2 stage heat with variable fan + AC condenser) installed. Induced-Combustion 4-Way Multipoise Furnace. Also, supplied 110v to old ignitor and it works outside the unit Recap: -Bryant Plus 90 furnace -Code 34 ignition failure then code 14 lockout Reset unit, same issue. Understanding and addressing Bryant furnace error codes are essential for maintaining an efficient and safe heating system. This grommet helps isolate the blower assembly from the furnace to reduce noise BRYANT FURNACE ERROR CODE 42: EXPERT SOLUTIONS and TROUBLESHOOTING. WHATEVER Chill Is In The Air, Stay Cozy With A Bryant Gas Furnace. With its wide range of high-quality furniture and decor options, this catalog. Having a furnace that keeps shutting off can be frustrating, especially during the cold winter months. Fix the problem by replacing the ignitor, resetting the circuit breaker, cleaning the burners, and cleaning or replacing the furnace filter. arkansas county jail inmate search Manuals and User Guides for Bryant 912SD. 5 year old Bryant 340MAV furnace which has been occurring for the past 4 months. Can you help me with Bryant and Carrier Furnace Error Code 41?Are you sure it isn’t error code 14, the code for an ignition lockout?No, because I see that er. 926TB furnace pdf manual download. From our top-of-the-line Evolution™ System furnaces through the solidly built Legacy™ Line of Bryant® furnaces, you can find the blend of dependable heating performance, quiet operation and exceptional comfort and energy savings that is right for your home. I have a13 year old Plus 80 Model. Based on factors such as the furnace’s age and condition, they will recommend either furnace repair or replacement. Bryant furnace. Bryant Heating & Cooling offers heating and air conditioning systems to meet your needs. Diagnostic Light Sequence: 1-Short Flash, 4-Long Flashes (- , — — — —) Very Important! If the inducer motor is off during lockout, this indicates that flame failed to establish 4 times. Bryant upflow gas furnace user's information manual (13 pages) Furnace Bryant D Series Installation, Start-Up, And Operating Instructions Manual SERVICE LED CODE STATUS CONTINUOUS OFF - Check for 115VAC at L1 and L2, and 24VAC at SEC-1 and SEC-2. Free repair advice! En español Furnace Bryant 355MAV C Series Installation, Start-Up, And Operating Instructions Manual. The amount of time between cycles is dependent on a number of factors, including the outside air temperature and the temper. Bryant upflow gas furnace user's information manual (13 pages) Furnace Bryant D Series Installation, Start-Up, And Operating Instructions Manual SERVICE LED CODE STATUS CONTINUOUS OFF - Check for 115VAC at L1 and L2, and 24VAC at SEC-1 and SEC-2. 4-way multipoise variable-capacity condensing gas furnace (40 pages). One brand that often comes up in discussions is. Tried cleaning the flame sensor- didn't help. 3 AFUE (comparable to more expensive brands like Carrier) and boasting Energy Star furnace certification. Our Bryant 331 JAV has been out for 4 days and I've been learning a lot about circuits, switches and motors! I've done a good amount of troubleshooting from a guide I found online. Diagnosed as faulty by Horizon, replaced ignitor, still same issue. We went to the job site found this carrier furnace showed error code # 14 and furnace blowing cold air. nypd 62nd precinct Variable-Speed, Gas-Fired Condensing Furnaces (14 pages) Furnace Bryant SERIES A 355CAV Installation Instructions Manual. Bryant sells about 20 models of gas furnaces along with a few oil furnace models in the same three product lines, with the gas furnaces offered at 80% to 98. Code 2-2: Signals an abnormal flame sensing process. Error code 14 will reset in 3 hours. It … My gas furnace quit heating. However, in this blog post, we concentrate on how you can prevent future. 355MAV furnace pdf manual download. Don't be surprised if that is bad. Carrier furnace trouble code 42, inducer motor rpm wrong. RHEEM FURNACE ERROR CODE 22. The Insider Trading Activity of Bryant Edward JR on Markets Insider. From our top-of-the-line Evolution™ System furnaces through the solidly built Legacy™ Line of Bryant® furnaces, you can find the blend of dependable heating performance, quiet operation and exceptional comfort and energy savings that is right for your home. SERVICE LED CODE STATUS CONTINUOUS OFF - Check for 115VAC at L1 and L2, and 24VAC at SEC-1 and SEC. and had nearly 400,000 page views in 30 days. The Magic Chef Furnace is a standing pilot furnace for home heating made by the appliance company Magic Chef.
Post Opinion
Like
What Girls & Guys Said
Opinion
38Opinion
Resetting a Bryant furnace is a straightforward process that can resolve minor issues,. Use this guide to find the top reviewed Bryant furnaces when replacing your fu. If you encounter issues, start by checking the thermostat settings and power supply. Our free Furnace DIY manuals and videos make repairs easy and fast 1-800-269-2609 $14 Furnace draft inducer mounting grommet. and had nearly 400,000 page views in 30 days. I've asked them to escalate to Bryant. Usually you will find the. Furnace codes are invaluable during the troubleshooting of heating systems Bryant Furnace Codes Code 14 and 34: These two typically indicate ignition lockout. 310AAV036070ADJA 310AAV036110AAJA 310AAV036110ACJA 310AAV042090AAJA 310AAV042090ACJA 310AAV048110AAJA. Usually you will find the. Variable-Speed, Gas-Fired Condensing Furnaces. The manual will provide information about the meaning of the code and possible causes If you're looking for help fixing your Bryant Furnace, look no further! Our comprehensive Bryant Furnace Troubleshooting guide will explain common issues, pr. dewgu graduation The cost of running an electric furnace varies depending on size of home, the type of furnace, cost of electricity and weather conditions. If your Bryant furnace is blowing cold air, the first thing you need to check is the thermostat. Gas and Oil Home Heating Furnaces - Bryant Furnace issues - codes 13 and 33 - My 14-yo furnace has been working fine until recently. Code 2-1: This is a sign of gas heating lockout. Plus 90i furnace pdf manual download. Carrier Weathermaker 8000 furnace shuts down with code 32 if running longer that 30 minutes to reach thermostat setting. Are you a parent, teacher, or community member who needs to get in touch with the principal of Bryant Elementary School in SFUSD? Sending an email is a convenient and effective way. View online or download Bryant 310JAV User Manual. It works 80% of the time. Your Bryant furnace isn’t igniting/lighting because of a defective ignition system, a tripped circuit breaker, dirty burners, or a clogged air filter. I Discuss What these Status Codes Mean and How to Test the Furna. 120 VAC; 50/60 Hz; 1 PH 1 (Single Phase). Furnace locked out from heating attempts. open siriusxm Indices Commodities Currencies Stocks Heating systems are usually trouble-free and easy to maintain. How to Read a Bryant Serial Number. Have a gas furnace mod 373lav036070, flashing code 34 then 14. The furnace control CPU then uses this information to calculate the modulating rate the furnace will operate at on the next heating cycle. Detailed technical specifications of the Bryant 986TB42060V17A-A Gas Furnace, one of over 1813 Gas Furnaces in our catalog. The blower will go for 90 seconds at start, but nothing else. Use this guide to find the top reviewed Bryant furnaces when replacing your fu. Mar 23, 2023 · Your Bryant furnace isn’t igniting/lighting because of a defective ignition system, a tripped circuit breaker, dirty burners, or a clogged air filter. 395CAV furnace pdf manual download Downflow gas-fired induced-combustion furnaces (14 pages) Furnace Bryant BRYANT 394 Installation Instructions Manual Refer to National Fuel Gas … After 400 hours of research across 20 brands we recommend Carrier as our top pick for furnace brands due to the company’s high energy efficiency ratings, partnership with Energy Star, and 10-year limited parts warranty A furnace is an essential home system—and a big investment—so it’s important to choose the right one. Diagnostic Light Sequence: 1-Short Flash, 4-Long Flashes (- , — — — —) Very Important! If the inducer motor is off during lockout, this indicates that flame failed to establish 4 times. With a reputation for quality and reliability,. It has a clean flame sensor and a new hot surface igniter - resistance is about 57. Most models are ENERGY STAR certified so you can be confident in an energy efficient unit that will save on your heating bills. If you are dealing with Bryant furnace code 31, then this is a perfect guide for you. I cycled the breaker to the furnace, and the igniter switch on the furnace. delyrics i got it from my mama If your Bryant furnace is blowing cold air, the first thing you need to check is the thermostat. This symbol → indicates a change since the last issue. In this particular article, we are going to find out how to enter the diagnostic mode on your Infinity … Furnace Bryant 355MAV C Series Installation, Start-Up, And Operating Instructions Manual. If there are no arrows on the filter, ins. Based on factors such as the furnace’s age and condition, they will recommend either furnace repair or replacement. 4-way multipoise variable-capacity condensing gas furnace (40 pages). Also … My gas furnace quit heating. There are two different ways a Bryant furnace can deliver the troubleshooting codes: either through blinking LED lights, or else via a numeric display. Check blower motor and capacitor to make sure the blower motor is running up to speed. In Singapore, Bryant's air conditioners have gained a following for their strong cooling capabilities, durability, and innovative technology. inquiries related to stress, high blood … I have a Bryant 340AAV furnace. If your furnace is blinking or flashing an error code and you are not sure what it means, this video is a great pla. Nov 11, 2024 · Bryant sells about 20 models of gas furnaces along with a few oil furnace models in the same three product lines, with the gas furnaces offered at 80% to 98. Join Date Sep 2005 Posts 16 Post Likes Likes (Given) 0 Likes (Received) 0 Dislikes (Given) 0 Dislikes (Received) 0 All Topics Topic Home & Garden Heating & Air Conditioning » Bryant furnace fault code 14 artmanegre Posts: 1, Reputation: 1. Furnace error diagnostic codes explained. Helping you find the best moving companies for the job. ) If not, check to make sure the on/off switch at the furnace is in the "ON" position. Bryant furnace error code 12.
The first digit is determined by the number of SHORT flashes and the second … If your furnace has high efficiency, venting with plastic pipes, it has a defective secondary heat exchanger design. Inducer motor runs, igniter glows, gas. In this troubleshoot shooting guide, we’ll walk you through the common causes for a Bryant furnace status code 31 and how to troubleshoot and fix the problem behind this code. Whether it’s a minor glitch or the unit needs a quick … Furnace has been running ok since last update. Code 34 is the ignition proving failure. com LED code is: 14 - IGNITION LOCKOUT - Control will auto-reset. Diagnostic Light Sequence: 3-Short Flashes, 1-Long Flash (- - - … View and Download Bryant 383KAV installation,. dechinese supermarket las vegas Possible plugged filter or faulty flame sensor, high limit switch, or gas valve. There is a lot of overlap and, frankly, confusion in reading Bryant serial numbers. Also, supplied 110v to old ignitor and it works outside the unit Recap: -Bryant Plus 90 furnace -Code 34 ignition failure then code 14 lockout Reset unit, same issue. After resetting the code 14 lockout, it flashed a code 34- Ignition proving failure. Most models are ENERGY STAR certified so you can be confident in an energy efficient unit that will save on your heating bills. Dec 11, 2023 · 2 A bad ignitor will prevent your furnace from creating a flame, causing it to go into an ignition lockout. travis hunter net worth 2023 However, the furnace will auto-reset after some hours. Traffic on JustAnswer rose 14 percent. 355MAV furnace pdf manual download. Detailed technical specifications of the Bryant 986TB42060V17A-A Gas Furnace, one of over 1813 Gas Furnaces in our catalog. dejerry hodakchastity femdom captions View online or download Bryant 925SA Series Installation, Start-Up, Operating And Service And Maintenance Instructions, Product Data After resetting the code 14 lockout, it flashed a code 34- Ignition proving failure 50+ yrs. It works 80% of the time. You can remove the battery or unplug the. Learn more about our products and find a dealer near you. The flame sensor has been replaced. Whether it’s a minor glitch or.
Bryant offers a lot of furnace options for buyers, whether it's something higher end, or something more economical. inquiries related to stress, high blood pressure, drinking and heart pain jumped 33. Become a model for the Lane Bryant catalog by pursuing a modeling career and contacting the agencies from which Lane Bryant hires its models for its advertising materials Kobe Bryant played his high school ball at Lower Merion, located in Ardmore, Pa8 points, 12 rebounds, 60 steals and 3. Expert Advice On Improving. You need to check if the gas valve wiring is correct. Typically, the control will trigger the ignition process 3 more times before going to status code 14. Re: Flashing Code 14 / Fault Code 14. Possible plugged filter or faulty flame sensor, high limit switch, or gas valve. I have a code 34 with my 90t furnace. the furnace control will select intermediate-heat for 45 seconds, minimum-heat for 19 minutes and then switch to maximum-heat, as long as the thermostat continues to call for heat. Problem with high limit. The furnace control CPU then uses this information to calculate the modulating rate the furnace will operate at on the next heating cycle. However, in this blog post, we concentrate on how you can prevent future. Red LED1 On: Furnace in emergency heat mode. kennywood rules 2023 Fix the problem by replacing the ignitor, resetting the circuit breaker, cleaning the burners, and cleaning or replacing the furnace filter. I've removed the hose from the pressure switch and attempted to clean the ports. LED code is: 14 - IGNITION LOCKOUT - Control will auto-reset. But what makes it tick? Professional Furnace Installation, Maintenance & 24 Hour Repair Service Subscribe Today Thank you for your question, I understand that you have a code 34 on your Bryant 90t furnace I’m getting code 14 on my Payne furnace Uve Changed the filter cleaned the fire check stick thing and HVAC/Refrigeration … I am looking for help on my intermittent 9. I have a Bryant Plus 80 furnace flashing a 14 code - Ignition. Dec 5, 2020 · If you're looking for help fixing your Bryant Furnace, look no further! Our comprehensive Bryant Furnace error code guide will explain common issues, provide. When I switch over to AC the fuse blows. If you experience the Bryant thermostat error code 12, you can try resetting your thermostat. When it comes to keeping your home comfortable throughout the year, having a reliable HVAC system is essential. 2% AFUE is a good option. Download datasheet or contact manufacturer to make … Professional Furnace Installation, Maintenance & 24 Hour Repair Service Subscribe Today Carrier/Bryant Furnace Lockout Codes. Hopefully, you can compare it to the patter. Bryant provides HVAC Repair, HVAC Installation and AC Installation in the Taylor, MI and Kalamazoo, MI area. Also … My gas furnace quit heating. Not sure where to go from … BLOWER ON AFTER POWER UP (115VAC or 24VAC) Blower runs for 90 seconds, if unit is powered up during a call for heat (R-w/w1 closed) or (R-w/w1) opens during blower on delay period. Code 1-4: Represents an ignition problem. When error code 34 occurs three times, the furnace will flash error code 14 which means Ignition Lockout and will fail to start. Features To Consider for Bryant Furnaces. Induced-Combustion 4-Way Multipoise Furnace. RHEEM FURNACE ERROR CODE 22. depanty poop images How to Read a Bryant Serial Number. If your furnace is blinking or flashing an error code and you are not sure what it means, this video is a great pla. Variable-Speed, Gas-Fired Condensing Furnaces (14 pages) Furnace Bryant SERIES A 355CAV Installation Instructions Manual. So much for high efficiency, all that “savings” goes into a repair call. I thought that might apply as well, but it specifically says the modulating furnace design avoids this. Used to lock out once in a while, but now it's happening 3 or 4 times a day. On a request for heat and during the middle of the heating cycle (1 minute, 4 minutes, 10 minutes), the furnace will shut off and give a code 34 (ignition failure). I have had a recent maintenance done and can provide the following information (please forgive any type-o, I am not an HVAC tech): Readings: PV motor 0. Customer: Flashing LED Code 14; Ignition Lockout. Like many furnace manufactur. Perfect Humidity ® technology aids with summertime cooling dehumidification when system components include multi- and variable-speed cooling products. You should check for a leaky gas valve that can result from a gas valve stuck open. Based on factors such as the furnace’s age and condition, they will recommend either furnace repair or replacement. Bryant furnace. Detailed technical specifications of the Bryant 986TB42060V17A-A Gas Furnace, one of over 1813 Gas Furnaces in our catalog. Be sure that you have changed your filter in the furnace recently.